Electrical Designer Guide

Design procedure, products and reference for electrical designers

Evaporative cooler circuits: wiring, controls and the water you are designing around

In hot, dry climates the evaporative cooler is still the cheapest way to cool a house, and in cities like Tucson, Phoenix and Las Vegas you will find thousands of them on flat roofs. For the electrical designer they are an unusual load: a motor, a small pump and a water supply sitting together on a roof, often a long way from the panel. This guide covers how to specify the circuit, the controls and the protection.

The load

A residential down-draft or side-draft unit typically carries a two-speed blower motor of 1/3 to 1 horsepower and a recirculating pump drawing well under one amp. Read the nameplate rather than the brochure. Size the branch circuit conductors at 125 percent of the motor full-load current from the NEC tables, and select overcurrent protection under Article 430 for the motor rather than treating the unit like a general-purpose receptacle load.

Disconnect and location

The code requires a disconnecting means within sight of the unit. On a roof that usually means a weatherproof, lockable switch mounted on the cooler stand or curb. Keep it upslope of the unit and clear of the drip line. Every evaporative cooler leaks eventually: a float valve sticks, a pad frame cracks or the bleed line clogs, and the water runs wherever the roof falls.

Water and the roof penetration

The most common fault we see is not electrical at all. It is the duct and cable penetration through the roof deck. When the curb flashing fails, water from the cooler pan follows the duct straight into the ceiling below, and it finds the light fixtures and junction boxes on its way. A stained ceiling around a supply register in the middle of summer, when it has not rained, is almost always the cooler. By then the drywall and insulation are wet, and homeowners need water damage repair crews in Tucson as well as an electrician, because a saturated ceiling has to be opened and dried before anyone can sign off the wiring inside it.

Controls

Use a wall control with separate pump and fan functions so the pads can be pre-wetted before the blower starts. A pump-off "vent" setting is useful in the shoulder seasons. Many newer controls add a timed pad-dry cycle that runs the fan with the pump off before shutdown, which reduces mineral build-up and mold in the pads. Where the cooler shares a duct with a refrigerated system, interlock the two so they can never run together.

Protection

Provide GFCI protection where the code calls for it on outdoor equipment and on any service receptacle near the unit, and use wet-location rated fittings and liquid-tight flexible conduit for the final connection. Bond the metal cabinet. Finally, put a seasonal shutdown in the operation notes: drain the pan, close the supply valve and open the disconnect, so a winter freeze or a stuck float cannot flood the roof while the house is heated by other means.